How to force an update?
Message
 
À
19/09/2005 16:27:20
Information générale
Forum:
Visual FoxPro
Catégorie:
Gestionnaire d'écran & Écrans
Divers
Thread ID:
01051018
Message ID:
01051030
Vues:
17
>I find that the value displayed in the listbox is always one cycle (one change) behind the value set by the optiongroup. I've concluded (I think) that the listbox refresh triggered by the optiongroup's interactivechange is firing before the new value is saved into the table. I've tried fixing the problem by moving the listbox refresh call to the optiongroup's valid event but the same problem is apparent.
>
It might be the listbox.displayValue is not being updated to reflect the listbox.value