>What I usually do is to open the SCX as a table and delete the record mentioned in the error - 32 in this case. Pack the table and see if you can modify it - if many things have gotten scrambled you may have to delete several records.
>
>Jerry Ritcey
Thank you for your help. What I had to end up doing is creating several new sub-classes of pageframe, one for each number of tabs I had in the various forms (FasPageFrame2, FasPageFrame3, FasPageFrame4, etc.), and then using your suggestion and that of Chad, I went into the table for my forms and changed the Class reference to the sub-class of pageframe corresponding to the number of tabs I had in the form. Saved me a lot of work!!
Thanks again.
Jere Wilson
N:deavor Systems, Inc.