Level Extreme platform
Subscription
Corporate profile
Products & Services
Support
Legal
Français
How to avoid fullpath in IMPLEMENTS line?
Message
 
 
To
23/10/2006 07:22:07
General information
Forum:
Visual FoxPro
Category:
COM/DCOM and OLE Automation
Environment versions
Visual FoxPro:
VFP 8 SP1
OS:
Windows XP SP2
Network:
Windows 2003 Server
Database:
Visual FoxPro
Miscellaneous
Thread ID:
01163889
Message ID:
01163894
Views:
17
This message has been marked as the solution to the initial question of the thread.
Try
* Generic ProgID
IMPLEMENTS ApplicationEvents IN "outlook.application"
* ProgID
IMPLEMENTS ApplicationEvents IN "outlook.application.10"
* TypeLibGUID
IMPLEMENTS ApplicationEvents IN {00062FFF-0000-0000-C000-000000000046}#9.1
>I re-post my question, because answers was not correct before.
>The question is..
>I need to IMPLEMENTS MS Outlook Item Interface
>In the application I use IMPLEMENTS ItemEvents IN "c:\programme\microsoft office\office10\msoutl.olb"
>Without fullpath IMPLEMENTS not work.. even with SET PATH TO.. functions, macro etc..
>
>Is there good solution for this problem? Maybe CLSID?
>
--sb--