>In the past three weeks, I have had two users complain of sporadic "Error reading file / error # 1104" messages. This on a stable APP, which is used by literally hundreds of work stations at many locations. In pursuing the problem, I have Isolated the particular differences of these machines -- both have the new 100 megahertz bus speed on the motherboard, both connect to a Novell File Server using Etherlink 100 base-T ( fast ethernet ), and both are running Windows '95 B. Other stations on the same server never get the message, these include users with Windows '95 B and 100 base-T ( fast ethernet ), in addition, there are other workstations running Windows '95 and '95a, and NT both with 10 base-T and 100 base-T.
><><><><><><><><>
>This seems to point to the 100 megahertz bus speed, since this hardware is on the bleeding edge. I have two questions:
>
>1) Has anyone else seen this problem?
>
>2) How do I solve it?
>
>Thanks in advance.

If the client's are using Client32 for Novell, you may want to try the new release (2.5?). There is a problem with the old client and data access.


Wayne
Wayne Myers, MCSD
Senior Consultant
Forte' Incorporated
"The only things you can take to heaven are those which you give away" Author Unknown