>Hi John,
>
>When I attach to the network as \\SYS I can only access one file at a time for either Win95 or WinNT. The drive is normally F: with W95 because the Win95 PCs have smaller hard drives than the newer machines which run WinNT. There are exceptions to this.
>
>With WinNT when I map the drive G: FPW runs pretty much normally. An exception is when I try to generate a screen or rebuild a project that has a screen. That's when I get the I/O error.
>
>With Win95 when I map the drive to F: FPW runs normally.

Hi Pete,

I'd suspect that the problem may have something to do with you CONFIG.FPW file. If you've hard coded the PATH or the locations of genscrn, etc. with a drive specifier this may be causing the problem. If so, the way around this may be to include a COMMAND = statement for a program that will set the paths according to the current value of SYS(5).

When FPW opens and it notes that the location of the project has changed you should be prompted as whether or not to make the location the current default. You should indicate that you do. FPW will then change all the path references in the the project automatically.

hth,
George