Level Extreme platform
Subscription
Corporate profile
Products & Services
Support
Legal
Français
Crystal reports then RMChart gives C0000005 error
Message
From
03/09/2008 13:04:36
 
 
General information
Forum:
Visual FoxPro
Category:
ActiveX controls in VFP
Environment versions
Visual FoxPro:
VFP 9 SP2
OS:
Windows XP
Network:
Windows 2008 Server
Database:
MS SQL Server
Miscellaneous
Thread ID:
01344403
Message ID:
01344563
Views:
14
There are several things listed on the wiki. Just search for C5.

>Thanks for the suggestion. Unfortunately it does not fix it.
>
>I rebuilt it in VFP7 and it gives the same C5 error as happens with VFP9.
>
>I know about Doug H's suggestion about WITH ... ENDWITH being the cause of some C5 errors. However, in this case, because the two options run fine independent of each other, and the error only arises when the form that has the RMchart activeX follows the form with Crystal reports, it must be some kind of interference form the RMchart activeX control.
>
>Any other ideas on what I can try to resolve this?
>
>Cyril
Craig Berntson
MCSD, Microsoft .Net MVP, Grape City Community Influencer
Previous
Reply
Map
View

Click here to load this message in the networking platform