>>>Thanks for your time, Cetin
>>>
>>>I have NT workstation 4.0 and That personilazed size doesn't exist in printer setup dialog. Do you know another manner?
>>>Can I use escape sequences with driver generic? I don't print in graphic mode, I need print in text mode only.
>>>
>>>Thanks again!
>>Enrique,
>>You could use escape sequences with generic driver. ie: ??? chr(27)+"E" would directly send escape+"E" to printer port (this requires port not captured and local). In NT too AFAIK generic printer setting supports personalized size though.
>>Cetin
>
>Cetin,
>
>I don't understand very well what is Port Not Captured. Printer Manual says:
>
>ESC C n Set Page Length In Lines
> n = number of lines (1-127)
>
>So, I execute ??? CHR(27)+'C'+'43' but only appears a Job Printing in Printer Window.
>
>Returning to Generic/Text Only Driver. I don't see the personalized size either in control panel and page setup window. :-(
>
>Thanks Again!
Not captured, I mean in details window you should see printer is connected directly to lpt1: port with no \\server\queue style remote connection. I don't think you'd be able to see page size in control p. or page setup if using esc sequences (they change it on the fly sending control commands directly to printer). Last I think syntax is wrong there :
??? CHR(27)+'C'+chr(43)
Cetin