Collating sequence & Vfp 6.0
Message
De
13/10/1998 09:49:00
Dragan Nedeljkovich (En ligne)
Now officially retired
Zrenjanin, Serbia
 
 
À
12/10/1998 13:44:28
Information générale
Forum:
Visual FoxPro
Catégorie:
Autre
Divers
Thread ID:
00145955
Message ID:
00146195
Vues:
26
>I have problem with my old tables created with vfp5.0 and fpw2.6. Vfp6.0 refuse to open it and return this message: "Collating sequnce : "GENERAL" is not found". Is there anyone who knows something about "collating sequences" in vfp6.0? Is there some compatibilities bug in vfp6.0 ? I know most of you haven't problem with collating sequences or Code pages, but ...
>

You're probably using codepage 1250; it doesn't have the collating sequence "General", but it has "Slovak", "Czech", "Polish", "Hungarian". I think you could go with the first one - it works for me.

In previous versions of VFP you could use any collating sequence, regardless of CpCurr() settings; now they have to correlate.

Lep pozdrav, zemljaèe :)

back to same old

the first online autobiography, unfinished by design
What, me reckless? I'm full of recks!
Balkans, eh? Count them.