Plateforme Level Extreme
Abonnement
Profil corporatif
Produits & Services
Support
Légal
English
Wanting to go from Drive Letter to UNC any advice
Message
Information générale
Forum:
Visual FoxPro
Catégorie:
Autre
Divers
Thread ID:
00153439
Message ID:
00154826
Vues:
21
>This is not a problem with the use of UNCs; it has to do with how your Novell network is set up. Novell 3.1x and 4.x in bindery emulation mode requires you to log into the server, one server at a time, either by explicit login or attachment. Attempting to map a resource (printer or drive) or examine the details of shared resources on a Netware server forces the login, but a simple UNC reference does not. A Novell server managed through an NT domain or via NDS is logged in when the domain or tree is accessed, avoiding the problem neatly. If you ATTACH the servers in your NetWare login script (as opposed to actually mapping a resource) you'll find that UNCs for the Attached servers will resolve normally.
>
We are using NDS here (IntraNetware 4.11) BUT I'm not sure what the other servers here are using. I *think* they are using the same. I am aware that the problem seems to be native to Novell from previous discussions with people who have had no problems with this on NT. It's just that some of my applications only display info on success of IF FILE(...) - they don't work on my PC but do work on the PCs they are intended for. (I have NO drives mapped - to ensure that my apps work without them).
Nigel B Coates
NBC Software Services
Dublin, Ireland.
eMail: Nigel.Coates@NBCSoftware.com
Précédent
Suivant
Répondre
Fil
Voir

Click here to load this message in the networking platform