Have you tried the "brute force" method by using two report variables?
old_key = cur_key
cur_key = keyvalue
(make sure that the variables appear in the specified order -- set the initial values so that they're set to the desired types so that you don't get an error in the print when clause)
in the print when of the "continued" message, use expression keyvalue==old_key.
>Hi All:
>
>In the report header, I want to say 'Continued' if it goes for more than one page. My method of doing this is not working.
>
>This is what I'm doing:
>
>In the program that issues the REPORT command, I say:
>
>
>llReportCont = .f.
>
>
>In the Group Header I say:
>
>
>'Section' + SectionCode + iif(llReportCont, ' (Continued)', "")
>
>
>Then in the group header, the 'Upon Exit' I say:
>
>
>llReportCont = .t.
>
>
>And finally in the Report footer in the 'Upon Entry' (doesn't really matter which):
>
>llReportCont = .f.
>
>
>This is not working. What is wrong?
>
>Thanks,
>
>Yossi