Broken Hour Meter
Message
De
30/11/1998 21:47:04
 
 
À
30/11/1998 19:43:39
Information générale
Forum:
Visual FoxPro
Catégorie:
Programmation Orientée Object
Divers
Thread ID:
00162599
Message ID:
00162633
Vues:
20
>>I have an application that schedules Preventive Maintenance for equipment. Most of the equipment uses an hour meter. I log in the hour meter reading into a table and use that along with the last time the PM was done to schedule the PM's. From time to time a meter will break and the Maintenance person will replace it. We don't have a way to "run up" the new meter so it starts at 0. Now the problem is how to add in the last good meter reading to the file each time a new meter reading is taken. Does any one have any thoughts on this? Should I have a file with the broken meter reading and add that to any readings taken some how???
>>
>>
>>Thanks
>
>How are you identifying the meter in the table?
>A "meter history" table with a key of "location" or some such ID and I suggest a "meterid", "startdate" and "startreading" field be set up. Then when you do your PM calcs you use the details in this file to modfiy the calculations when readings cross over a change of meter barrier.
>
>HTH

Hi David,

The meter reading is identifyed by the AssetId field. All tables that relate to equipment use the AssetId field as the relation. I have a seperate meter reading table that has the AssetId and date and the meter reading for each time the meters are read.

Are you saying that I could have a seperate field for meter adjustments in the equipment table and that I add or subtract (as needed) the value in the meter adjustment field??? Sounds good to me as I think about it. So if the meter adjustment field is 0 (ie. the meter has never been replaced) the calculations do nothing... If there is a value there then if I need total hours I add that value to the current reading... What do you think?

Thanks