>I have a system that was built in 2.6. Someone just installed a copy of this system on an NT workstation machine and they get an I/O error when opening. If they put a CD in the drive, it works ok. What's the deal???
>
Hi Judy,
Probably what happened was that when the application was compiled, the temporary files were being sent to the D: drive. Here's how to fix it. First, make sure that the CONFIG.FPW file indicates that all temp files are directed to C: (TMPFILES, PROGWORK, EDITWORK, etc.). Second, start FPW, then open the project as a table (USE MYPROJ.PJX). Third, from the command window, REPLACE ALL OBJECT WITH "". This will clear the references. Last, re-compile with the Compile (or is it rebuild?) All check box checked. That'll do it.
George
Ubi caritas et amor, deus ibi est