>>>>>We installed VFP 5.0 Application on client stand alone PC.
>>>>>
>>>>>It was running fine until they installed WIN'98 Network.
>>>>>
>>>>>Now when they start our application message "Error locating
>>>>>config file. Bad path ..." appears. After that "Invalid path
>>>>>or file name Kernel32".
>>>>>
>>>>>We tried to reinstall - the same result.
>>>>>
>>>>>Please, help.
>>>>Irina,
>>>>Start to check if tmpfiles (editwork, sortwork, progwork) are set to a RO or nonexistant path.
>>>>Cetin
>>>
>>>
>>>Right, but config file is not included into the project.
>>>So it should work with Windows temp directory.
>>
>>And vfxxxx.dll should be in user's windows\system directory. How they "setup" the app to their machine ? Just a map to server directory ?
>>Cetin
>
>They run it on a workstation without using any other resources.
>Irina
Irina,
Check autoexec.bat file for path statement. If there is a missing ; add it. Alternatively create a dummy config.fpw at home() (windows\system) so VFP could finish its search.
Cetin