>I would like to say it was a typo. I knew better just not watching what I was doing. Thanks for the respond, Randy

Don't compile a CONFIG.FPW into the EXE. Make it a separate file, but distribute with the application. It should be in the startup folder of the EXE. You could also force the use of the config file with the -cMyConfig.FPW command like parameter.