>Under NT4.0, is it possible to automatically logoff and popup the logon screen when the user exit a VFP application?
>
>TIA
>S.H.
Another option is to add a timer to your main app. In the event fire of the timer fire the shutdown code. In every form on the app on the init of the form reset the timer. Not a perfect solution but is easy to do and doesn't drain system resources to have in place.