Using VFPCOM to bind to Outlook events (ItemSend for exa
Message
General information
Forum:
Visual FoxPro
Category:
COM/DCOM and OLE Automation
Miscellaneous
Thread ID:
00363457
Message ID:
00363493
Views:
13
Changing sys(2333, 0) to sys(2333, 1) didn't make any difference either.

Cheers,

Andrew

>Hi Walter,
>
>I tried sys(2333,0) in the application object's SendEmail() method, and the method appeared not to explode with a GPF when the SET STEP ON code was enabled (although it didn't make the note it was supposed to make). When I turned off the break though, it GPFd again - Timing problem perhaps?
>
>New method code:
>
* disable vtable binding to see if that avoids GPFs
>local lcSYS2333
>lcSYS2333 = sys(2333,2)
>sys(2333, 0)
>
>with this
>
>  local loMessage
>
>  loMessage = .oOutlook.createitem(olMailItem)
>
>  loMessage.UserProperties.Add('ToContactID', olNumber)
>  loMessage.UserProperties.Add('FromRep', olText)
>  loMessage.UserProperties('ToContactID') = this.GetCurrentContact()
>  loMessage.UserProperties('FromRep') = this.cInitials
>
>  loMessage.Recipients.Add(contactview.email)
>  loMessage.Recipients.ResolveAll()
>  loMessage.Display(.f.)
>
>endwith
>
>sys(2333, int(val(lcSYS2333)))
>
>Cheers,
>
>Andrew
>

>>Andrew,
>>
>>>No I haven't tried sys(2333) - I'll give it a shot, but I can't see why that would make a difference, there's not an ActiveX control being instantiated within VFP - it's a COM server.
>>
>>I know, thats why it is a shot in the dark.
>>
>>>I could be displaying my lack of complete understanding of things COM, but I thought these were two different things, or at least that one was a subset of the other.
>>
>>To be honest I don't know if they are related or not, I think it's worth a try.
>>
>>>I'm also not sure where I'd switch it on/off in the code. Because it's event driven and I don't even seem to get to the start of the event code, there doesn't seem to be an appropriate place to put the sys() call.
>>
>>How about before you instantiate the com-server ?
>>
>>Walter,


If we were to introduce Visual FoxBase+, would we be able to work from the dotNet Prompt?


From Top 22 Developer Responses to defects in Software
2. "It’s not a bug, it’s a feature."
1. "I thought I fixed that."


All my FoxTalk and other articles are available on my web site.