Walter Meester
HoogkarspelPays-Bas
Information générale
Catégorie:
Gestionnaire de rapports & Rapports
Walter,
>This is the problemline. You instantiate the CRPE autometion server in stead of the RDC automation server. You cannot use the smartviewer with a >report object created with the CRPE automationserver.
>If you change this into:
> m.loCrApp = CREATEOBJECT("CrystalRuntime.application")
> your app should run without problems.
Thanks a million. It WORKS!. It finally work!!!! Just to let you know that I spend the last couple of weeks figuring out why my code does't work. Thanks again. Now, what is the diferrence between a report object created with CRPE automation and RDC (CrystalRuntime.Application)? Aren't they suppose to be same report object ?
You seem to have done a lot research on CR to work in Vfp. I have searched your postings on CR in UT, and I found that you almost always reply any questions regarding CR. All those posting by you is always very valuable to those who want to use CR in Vfp. May I suggest that you do a help document or a general framework on CR ( if possible with examples and tips and traps) and post to UT in the files sections, so that anyone who is interested in CR may save them a lot of troubles searching the net for those answers. If you already have done that, could you please email me a copy?
Hope that's not a tall request. THANKS!!!
Jin
Précédent
Suivant
Répondre
Voir le fil de ce thread
Voir le fil de ce thread à partir de ce message seulement
Voir tous les messages de ce thread
Voir tous les messages de ce thread à partir de ce message seulement