Is there a better mscomm?
Message
Information générale
Forum:
Visual FoxPro
Catégorie:
Contrôles ActiveX en VFP
Divers
Thread ID:
00443243
Message ID:
00447170
Vues:
19
>>>I sort of have this working now. Two problems...
>>>
>>>1. When I change the senders RTS line, the receiver (VB activex DLL) oncomm fires three times.
>>>
>>
>>Sure - you're causing multiple events since you're 'pinging' the handshake line - OnComm sees two transits of the CTS line (RTS crosses CTS), which issues two comEvCTS, and probably a Send buffer not full (comEvSend) report.
>>
>
>I'm not sure why it would see two transitions. Just as a test I set it from high to low and with that I get three events. I have logged all
>the events by capturing and appending the event number to a string. I get three 3s in a row. I have not sent any data in this test.
>

3 is a comEvCTS, so you transit from default CTS state to high to low; I'd check the value of the CTSHolding property on every 3.
EMail: EdR@edrauh.com
"See, the sun is going down..."
"No, the horizon is moving up!"
- Firesign Theater


NT and Win2K FAQ .. cWashington WSH/ADSI/WMI site
MS WSH site ........... WSH FAQ Site
Wrox Press .............. Win32 Scripting Journal
eSolutions Services, LLC

The Surgeon General has determined that prolonged exposure to the Windows Script Host may be addictive to laboratory mice and codemonkeys