General information
Category:
ActiveX controls in VFP
>>>>I sort of have this working now. Two problems...
>>>>
>>>>1. When I change the senders RTS line, the receiver (VB activex DLL) oncomm fires three times.
>>>>
>>>
>>>Sure - you're causing multiple events since you're 'pinging' the handshake line - OnComm sees two transits of the CTS line (RTS crosses CTS), which issues two comEvCTS, and probably a Send buffer not full (comEvSend) report.
>>>
>>
>>I'm not sure why it would see two transitions. Just as a test I set it from high to low and with that I get three events. I have logged all
>>the events by capturing and appending the event number to a string. I get three 3s in a row. I have not sent any data in this test.
>>
>
>3 is a comEvCTS, so you transit from default CTS state to high to low; I'd check the value of the CTSHolding property on every 3.
FYI - Further testing has shown that this only happens on my NT 4 workstation. The wyse winterms which I plan to use the app on, don't
have this problem.
Previous
Reply
View the map of this thread
View the map of this thread starting from this message only
View all messages of this thread
View all messages of this thread starting from this message only