Hi Fred,
I do have a CONFIG.FPW file with the MVCOUNT set to 2048. Also the variable count is small enough not to require that setting. As I said, it runs fine when the startup PRG is run, or if the project is compiled without the ActiveDoc class.
>>I'm getting my feet wet with trying to run an application in a browser.
>>Everything works fine until the ActiveDoc class is added and set as main. it runs a short loader program which runs a form with a grid in it.
>>I get the error above whether I run it within VFP or use the run activedoc option in the tools menu.
>>If run the prg file it runs fine.
>>Anyone with suggestions as toi what I'm doing wrong?
>>
>>TIA
>
>Do you have a CONFIG.FPW that's being used by your application? If not, you'll need one with a line that has MVCOUNT=2048 or whatever number you may need. For VFP6, I think the default value is 1024. This setting will change the number of simultaneous variables you can have defined, and can only be adjusted by this entry in your CONFIG.FPW file.