Robert,
I was going to ask if you were CERTAIN that both machines were otherwise exactly identically set up in every other respect.
When I read *this* response I became more convinced than ever that there must be *some* difference between the two.
Good luck,
Jim N
>>Has anyone experienced the following rounding problem with Foxpro 2.6
>>for Windows running on an MMX processor?
>>
>>Create a DBF with one field - "field1" N 12,2
>>Create one record with a value of 3076.14
>>Issue the command:
>> ? ROUND(field1, 6)
>>
>>ON AN MMX MACHINE WE ARE GETTING THE RESULT OF 3076.139893
>>ON NON-MMX MACHINES WE GET THE CORRECT RESULT OF 3076.140000
>>
>>Any comments greatly appreciated.
>I tried it on a 233MMX and did not encounter the error