>Jim,
>Barge in, barge in!!! We have some old Telex terminal hooked up to an even older DEC machine. I've been able to determine thus far that it can handle wyse50, wyse50+, and wyse60 emulation, but unless you specify, wyse50 is default. I've tried the same character sequence under all 3 emulation types (it is the same string for all 3), but to no avail. The real bummer here is that the wyse50 +F16 (which, by the way, is CHR( 1 ) + CHR( 111 ) + CHR( 13 )) works just fine. This has become a vendetta. I will figure it out, no matter how long it takes. I will send you more info as it becomes available, but don't expect much soon. If you have any info you can share with me on this, I will trade you years off my life for it. Thanks Jim,
>John

that should be the wyse50 shift+F16, sorry, my shift got html'd out.