Level Extreme platform
Subscription
Corporate profile
Products & Services
Support
Legal
Français
Severe situation on bug
Message
From
31/07/2001 12:05:32
 
 
To
31/07/2001 12:00:34
General information
Forum:
Visual FoxPro
Category:
Troubleshooting
Miscellaneous
Thread ID:
00537068
Message ID:
00537804
Views:
52
>
>We use the COM mode. So, by default WWC does not include the SYS(2335) command. If I understand correctly, I should add this at the upper level somewhere. Does that mean, if in the code, I forgot to open a tabe for example, this will never happen again as the control will be returned immediately at the error level?
>
Add this at the Init of your main COM object or each COM object called by WWC.
Yes, the control will return immediately to the error handler instead of Open dialog box in unattended mode. Just read help for SYS(2335), there is a table with situations of dialog boxes, it includes the open dialog box too.
Vlad Grynchyshyn, Project Manager, MCP
vgryn@yahoo.com
ICQ #10709245
The professional level of programmer could be determined by level of stupidity of his/her bugs

It is not appropriate to say that question is "foolish". There could be only foolish answers. Everybody passed period of time when knows nothing about something.
Previous
Next
Reply
Map
View

Click here to load this message in the networking platform