Plateforme Level Extreme
Abonnement
Profil corporatif
Produits & Services
Support
Légal
English
Receiving an error message INVALID OFFSEEK
Message
De
04/09/2001 23:24:47
Stuart Ramsey
Medical Business Systems
East Gosford, Australie
 
 
À
04/09/2001 08:13:19
Information générale
Forum:
Visual FoxPro
Catégorie:
Autre
Divers
Thread ID:
00551995
Message ID:
00552318
Vues:
16
The error is usually a bad network connection, I have had a spate of errors caused by the client electing to get their cabling installers to do the install, because their really cheap, and they take every short cut possible.

You can run into problems when an existing 10Mb network is upgraded to 100Mb as the cabling requirements are far higher at 100Mb. i.e. minor packet loss at 10Mb goes off the scale at 100Mb.

I have developed the following to overcome this.

1. Use only brand name NIC'S & Switches. i.e. Intel, Bay etc. With the Switches pay attention to how much backplane or fabric it has, and how it queues the packets.

2. Have the cabling certified to at least 100Mb, with the following tests

100% of the cabling shall be tested for:

- Continuity
- Correct Sequence
- Reversed Pairs
- Transposition
- Split Pars
- Pair to Pair Near Cross Talk (NEXT)
- Power Sum Near End Cross Talk (PSNEXT)
- Attenuation
- Return Loss
- Power Sum Equal Level Far End Cross Talk (PSELFEXT)
- Phase Delay
- Delay Slew

Any other tests as deemed required by the manufacturer to obtain End-to-End Certification.



All tests required to satisfy your relevant Authorities
Précédent
Répondre
Fil
Voir

Click here to load this message in the networking platform