>>>>Rocky Boy...
>>>
>>>I allready pu olecontrol1 into my form (mscomm32.ocx), then I also pu command button into
>>>it also. In click event command button :
>>>thisform.olecontrol1.portopen=.t.
>>>thisform.olecontrol1.output="Test"
>>>
>>>There is an error while I click the button :
>>>- OLE ERROR CODE 0x800ALF45;UNKNOW OLE STATUSCODE
>>> in line thisform.olecontrol1.portopen=.t.
>>>Then I Ignored this things :
>>>- OLE IDISPATCH EXCEPTION CODE O FROM MSCOMM:OPERATION VALID ONLY WHEN THE PORT IS OPEN
>>>
>>>Any idea?
>>>Thank's
>>>Andri Thaslim
>>
>>what comm port do you try to open ?
>>are you sure that's correct or if it really a comm port not a modem or something like that ?
>
>I try to write into com2 (there is one Posiflex Pole Display for Cash Register whict connect to com2)
>and I'm using VFP 5.0 for my POS Application.
>
>The command in Dos is Like this :
>Procedure Disp_str
> parameters line1, line2
> line1= line1 + Space(20)
> line1= Left(line1, 20)
> line2= line2 + Space(20)
> line2= Left(line2, 20)
> comm_name= "COM2"
> xopen= fopen(comm_name, 1)
> if (ferror() != 0)
> return .F.
> endif
> dispchr= line1 + line2
> if (fwrite(xopen, dispchr, Len(dispchr)) <= 40)
> for c= 1 to Len(Trim(dispchr))
> =fwrite(xopen, Chr(9), 1)
> next
> =fclose(xopen)
> return .F.
> endif
> =fclose(xopen)
> return .T.
>
>
>What should I do to Convert that program into VFP5.0 ?
>
>Thank's
Hi Andri
May be you can find all answer you need in the help file that come with the CD of VFP5.0
the help file name is \OS\SYSTEM\COMM96.HLP
In this help file you will find some exemple that show you how can you translate your code
Hope this help
Rocky Boy...
Previous
Reply
View the map of this thread
View the map of this thread starting from this message only
View all messages of this thread
View all messages of this thread starting from this message only