Plateforme Level Extreme
Abonnement
Profil corporatif
Produits & Services
Support
Légal
English
Data Delay Across Network ?
Message
De
11/04/2002 16:51:13
 
 
À
10/04/2002 12:20:53
Information générale
Forum:
Visual FoxPro
Catégorie:
Base de données, Tables, Vues, Index et syntaxe SQL
Divers
Thread ID:
00643232
Message ID:
00643961
Vues:
9
Hi Ed,

I'm back - tried hacking the registry and it did not seem to help (like the closing of the table helped). Just to make sure I am adding in the proper parameter, this is what I did - could you check it for accuracy (if you know)?

Once into Regedit, go to HKLM, then "CurrentControlSet" (this is what I thought you meant by your CCS abbreviation), then \Services then \Mrxsmb and then highlight the parameters folder by clicking on it.

Then Right-Click (RC) on a blank spot in the right hand pane and choose "New", then choose "DWord Value". Change the title from "New Value #1" to OpLocksDisabled and save. The RC on new item and choose "Modify" and when that comes up type a "1" into the input area and make sure Hexadecimal is the radio button chosen. Save the change.

I did the same steps then for the \Lanmanworkstation\parameters folder inserting a value in there.

Should that do it? Do I have to reboot? The first time I started to insert it, I ended up creating a new folder underneath parameters and I did not think that was correct so I deleted it and instead just put a new value into the parameters folder.

Thanks,

Albert Gostick