Plateforme Level Extreme
Abonnement
Profil corporatif
Produits & Services
Support
Légal
English
Collating sequence error
Message
De
06/02/2003 05:45:38
Yh Yau
Ingenuity Microsystems Sdn Bhd
Kuala Lumpur, Malaisie
 
 
À
04/02/2003 12:05:01
Denis Filer
University of Oxford
Royaume Uni
Information générale
Forum:
Visual FoxPro
Catégorie:
Base de données, Tables, Vues, Index et syntaxe SQL
Divers
Thread ID:
00748800
Message ID:
00749757
Vues:
25
Denis,
I had errors with collating sequence before.
What happened was that we installed a Chinese language interpreter software to enable our VFP app to use chinese characters.
We did a reindex when the Chinese Interpreter (CI) app was running.
When we shut down the CI and run the app, the error message "collating sequence pin yuen.... not found" will appear. Restarting the CI software solve the problem.
To resolve the error permanently, we switched off the CI, deleted all cdx files from Dos Prompt, and did a reindex.
After which, we were able to run the app without the CI app in the background.
HTH.
Yau
Précédent
Suivant
Répondre
Fil
Voir

Click here to load this message in the networking platform