Ron,
How are you deploying it? Are you using InstallShield Express (ISX)? What merge modules are you including?
You need VFP8 Runtime, Visual C++ 7 Runtime and GDI+.
HTH.
>I have created a com-object that runs W2K server. When deploying with VFP7 it on this server (the runtime files are available) everything runs fine.
>When deploying it on a test machine (no VFP installed) and register it with dcomcnfg everything runs fine.
>
>Doing this with VFP8 to the W2K-server machine is giving me problem. Although it works fine on a test machine I can't get it to work with on the server. I keep getting the following message:
>OLE error code 0x80029c4a: Error loading type library/dll
>
>Works fine though on a different machine. Any suggestions why this is happening. I would like to distribute this exe.
>If I distribute the program as a dll and try to do this with COM+ I get the same error message.
>
>Any ideas why this is happening and how to avoid this?
>
>Regards,
>Ron
Larry Miller
MCSD
LWMiller3@verizon.netAccumulate learning by study, understand what you learn by questioning. -- Mingjiao