PRG blows up on APPEND BLANK command
Message
From
22/06/2004 17:46:01
Fabian Belo
Independent Developer
Argentina
 
General information
Forum:
Visual FoxPro
Category:
Other
Miscellaneous
Thread ID:
00916194
Message ID:
00916220
Views:
15
>I have a program (PRG) that has a fatal exception error every time at the same exact point in the program, the APPEND BLANK command. This is an Accounts Payables Transaction Posting program.
>
>What did I do wrong? Any ideas on this one?


From http://www.intergate.com/~dallen24/fox.htm

Error: Fatal Exception Code=C00000FD


People reported this problem when they move files between computers with different types of FAT (File Allocation Table). For example, Windows 98 to/from Windows NT/2000.

As I understand it, this problem is the result of a corrupted dbf file. Try to REINDEX and/or PACK your file. Might have to perform a COPY TO WITH CDX.
"Since I've read that alcohol is bad... I quit reading."