>>>>>>i'm not sure but, if you create your menu via quick menu the wizard duplicates the foxpro system menu for you to use as a template. if you run an app., foxpro disable the system menu, hense, if you run the template that foxpro has created for you it will behave the same way. i think....
>>>>>>
>>>>>>just a thought.
>>>>>
>>>>>But all the other quick menu stuff is running fine. It's just that one option.
>>>>>
>>>>>Thanks,
>>>>>
>>>>>Michelle
>>>>
>>>>
Michelle,
>>>>I think that thought is right. It seems you're in a state that you cannot use default "Exit" if you were just using default menu. It might be anything that's preventing an exit. Just for a sample :
>>>>
>>>>Try to change _mfi_quit with a command calling your shutdown routine (with a clear events).
>>>>Cetin
>>>
>>>I changed it to just "QUIT" and it works fine. Is there some reason I need to do a CLEAR EVENTS? Will just QUITting corrupt the data or anything?
>>>
>>>Thanks,
>>>
>>>Michelle
>>
>>
I never experienced a problem with just a "quit" but it doesn't mean it wouldn't cause any problems. An extra line wouldn't harm :)
>>Cetin
>
>True, but since I can only put one line there, an extra line means writing a program. Since it's only for in-house use, I'll just leave it as is unless someone tells me it's going to do something really bad. :)
>
>Thanks,
>
>Michelle
One line ? It could be a procedure. I think leaving it as is would do no harm. OTOH with one line you could call your UDF ExitApp() routine.
Cetin