Message
General information
Forum:
Visual FoxPro
Category:
ActiveX controls in VFP
Title:
Miscellaneous
Thread ID:
00614817
Message ID:
00614872
Views:
29
The code I gave you just shows the level of handling that may be required depending on your application. It in no way alters the .input of the control. Your previous observation of the toggling of the CTS line by the scanner makes me question its setup. Check that your control and the scanner agree on the method of handshaking. If timing was an issue, I would expect incomplete data versus none at all.

>Yes, I also commented out the code you gave me. It must have messed with the timing and the values of this.input. Now, it works on the first scan.
>
>This stuff if such a pain to debug!!!
>
>Thanks for the quick replies!
>
>>>>