Hi Tracy,
> it is as though fpd26 does not recognize
> that the value of lncount has changed...
correct - see my example!
the GET - rowsource stay's on the arrayelement which is defined by lncount when called the first time.
>Well I tested issuing a clear read and then another do ....spr
> but after a few times I get a too many reads error.
I was more thinking along the lines of creating a read-less screen, (directive #noread or something similar), issueing a clear ****GETS****,
calling the read-less .spr again and always calling a read under "your" control in your program code.
Sorry to be so vague, but I've been trying to loose the FPW-stuff - the dirty tricks department is always the first to loose the edge.
Regards,
thomas
Précédent
Répondre
Voir le fil de ce thread
Voir le fil de ce thread à partir de ce message seulement
Voir tous les messages de ce thread
Voir tous les messages de ce thread à partir de ce message seulement