Walter Meester
HoogkarspelNetherlands
General information
Category:
COM/DCOM and OLE Automation
HI Mike,
SET REFRESH takes two parameters. The second one is responsible for the local buffers. So a SET REFRESH TO 1,1 might work.
However, keep in mind that frequent refreshing loads the network and can lead to network performance problems. You might think of something else to notify the server app (Like DCOM or something)
Walter,
>I added
>set refresh to 1
>to both server and client,
>
>strangely, the SERVER improved from 1 - 2 to 0 - 1 seconds, but the CLIENT remains at about 5 seconds!