General information
Category:
Reports & Report designer
Yeah, I had just noticed that - we should have thought of that earlier. I saw that a CHR(27)+CHR(64) followed immediately by the below ignored the I-Prime command. Allowing a 2 second delay made it work OK. It was then I noticed the spooler popping up - Windows being once again too helpful. So much for 'print direct to printer'. Sigh. Glad you have it done.
>Thanks Jim, sending all of the codes in one shot instead of in separate ??? commands worked. It finally is working on all of the 3 forms that were exhibiting problems. Wish I had thought of that!
>
>Tracy
>
>>Tracy, try a CHR(27)+CHR(125)+CHR(0) as a replacement for your 'reset'. If the I-Prime is at default, the buffer finishes printing, and the pitch and quality go to power on defaults.
Previous
Reply
View the map of this thread
View the map of this thread starting from this message only
View all messages of this thread
View all messages of this thread starting from this message only